Product Category : Coated Glass - Coatings on NEXA
Type:
 
Product:
SunGuard® SNX 60 HT on NEXA 6
EN 1096-4:2018
Coated soda lime silicate glass intended to be used in buildings and construction works values as of April 2024
04mm05mm06mm08mm
Resistance to fire test (EN 13501-2) NPDNPDNPDNPD
Reaction to fire (EN 13501-1) A1A1A1A1
External fire performance (EN 13501-5) NPDNPDNPDNPD
Bullet resistance (EN 1063) NPDNPDNPDNPD
Explosion resistance (EN 13541) NPDNPDNPDNPD
Burglar resistance (EN 356) NPDNPDNPDNPD
Pendulum body impact resistance (EN 12600) NPDNPDNPDNPD
Resistance against sudden temperature changes and temperature differentialsK40404040
Wind, snow, permanent and imposed load resistancemm4568
Characteristic Bending StrengthMPa45454545
Direct airborne sound insulation (EN 12758)dB29 (-2;-3)30 (-1;-2)31 (-2;-3)32 (-2;-3)
Thermal properties     
Normal emissivity of coated glass surface εn (EN 12898) NPDNPDNPDNPD
Radiation properties     
Light transmission 𝛕V (EN 410) NPDNPDNPDNPD
Light reflection (coated side / glass side) ρV (EN 410) NPDNPDNPDNPD
Solar energy transmission 𝛕E (EN 410) NPDNPDNPDNPD
Solar energy reflection (coated side / glass side) ρE (EN 410) NPDNPDNPDNPD
Solar factor (coated side / glass side) g (EN 410) NPDNPDNPDNPD
Durability (EN 1096) CCCC
NPD = No Performance Determined
GUARDIAN EUROPE Sàrl
19, rue du Puits Romain
L-8070 Bertrange
G-D of Luxembourg
All values are nominal values and subect to product tolerances Disclaimer: The Information contained in this publication is a general description of glass products and GUARDIAN hereby disclaims all liability howsoever arising from any inaccuracy in or omissions from this publication and all the consequences of relying on it. It is the responsibility of the users of this information to ensure that the intended application of glass products is appropriate and complies with all relevant laws, regulations, standards, codes of practices and other requirements.