| SunGuard® SNX 60/28 |
EN 1096-4:2005 |
Coated soda lime silicate glass intended to be used in buildings and construction works values as of June 2016 |
04mm | 05mm | 06mm | 08mm | 10mm | 12mm | 15mm |
Resistance to fire test | | NPD | NPD | NPD | NPD | NPD | NPD | NPD |
Reaction to fire | | A1 | A1 | A1 | A1 | A1 | A1 | A1 |
External fire performance | | NPD | NPD | NPD | NPD | NPD | NPD | NPD |
Bullet resistance (EN 1063) | | NPD | NPD | NPD | NPD | NPD | NPD | NPD |
Explosion resistance | | NPD | NPD | NPD | NPD | NPD | NPD | NPD |
Burglar resistance (EN 356) | | NPD | NPD | NPD | NPD | NPD | NPD | NPD |
Pendulum body impact resistance (EN 12600) | | NPD | NPD | NPD | NPD | NPD | NPD | NPD |
Resistance against sudden temperature changes and temperature differentials | K | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
Wind, snow, permanent and imposed load resistance | mm | 4 | 5 | 6 | 8 | 10 | 12 | 15 |
Direct airborne sound insulation (EN 12758) | dB | 29 (-2;-3) | 30 (-1;-2) | 31 (-2;-3) | 32 (-2;-3) | 33 (-2;-3) | 34 (0;-2) | 36 (-1;-3) |
Thermal properties | | | | | | | | |
Normal emissivity of coated glass surface εn (EN 12898) | | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 |
Radiation properties | | | | | | | | |
Light transmission τV (EN 410) | | 0.66 | 0.66 | 0.66 | 0.66 | 0.65 | 0.64 | 0.64 |
Light reflection (coated side / glass side) ρV (EN 410) | | 0.07 / 0.09 | 0.07 / 0.09 | 0.07 / 0.09 | 0.07 / 0.09 | 0.07 / 0.09 | 0.07 / 0.09 | 0.07 / 0.09 |
Solar energy transmission τE (EN 410) | | 0.29 | 0.29 | 0.29 | 0.29 | 0.28 | 0.28 | 0.27 |
Solar energy reflection (coated side / glass side) ρE (EN 410) | | 0.49 / 0.42 | 0.49 / 0.40 | 0.49 / 0.39 | 0.49 / 0.37 | 0.49 / 0.33 | 0.49 / 0.32 | 0.49 / 0.28 |
Solar factor (coated side / glass side) g (EN 410) | | 0.33 / 0.34 | 0.34 / 0.33 | 0.34 / 0.33 | 0.34 / 0.33 | 0.34 / 0.33 | 0.33 / 0.33 | 0.33 / 0.33 |
Durability (EN 1096) | | C | C | C | C | C | C | C |