| SunGuard® SN 75 Lami 10mm |
EN 14449:2005 |
Coated LamiGlass intended to be used in buildings and construction works values
as of April 2018 |
4.6.2 | 5.5.1 | 5.5.2 | 5.5.4 | 5.5.6 |
Resistance to fire test | | NPD | NPD | NPD | NPD | NPD |
Reaction to fire | | NPD | NPD | NPD | NPD | NPD |
External fire performance | | NPD | NPD | NPD | NPD | NPD |
Bullet resistance (EN 1063) | | NPD | NPD | NPD | NPD | NPD |
Explosion resistance | | NPD | NPD | NPD | NPD | NPD |
Burglar resistance (EN 356) | | NPD | NPD | P2A | P4A | P5A |
Pendulum body impact resistance (EN 12600) | | 1(B)1 | 1(B)1 | 1(B)1 | 1(B)1 | 1(B)1 |
Resistance against sudden temperature changes and temperature differentials | K | 40 | 40 | 40 | 40 | 40 |
Wind, snow, permanent and imposed load resistance | mm | 10 | 10 | 10 | 10 | 10 |
Direct airborne sound insulation (EN 12758) | dB | NPD | 34 (-1;-3) | 34 (-1;-3) | 34 (-1;-3) | 34 (-1;-3) |
Thermal properties | | | | | | |
Normal emissivity of coated glass surface εn (EN 12898) | | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 |
Radiation properties | | | | | | |
Light transmission τV (EN 410) | | 0.79 | 0.79 | 0.79 | 0.79 | 0.79 |
Light reflection (coated side / glass side) ρV (EN 410) | | 0.06 / 0.06 | 0.06 / 0.06 | 0.06 / 0.06 | 0.06 / 0.06 | 0.05 / 0.06 |
Solar energy transmission τE (EN 410) | | 0.40 | 0.40 | 0.40 | 0.39 | 0.39 |
Solar energy reflection (coated side / glass side) ρE (EN 410) | | 0.43 / 0.26 | 0.43 / 0.27 | 0.43 / 0.26 | 0.43 / 0.25 | 0.43 / 0.24 |
Solar factor (coated side / glass side) g (EN 410) | | 0.44 / 0.44 | 0.44 / 0.44 | 0.44 / 0.44 | 0.43 / 0.44 | 0.43 / 0.44 |
Durability (EN 1096) | | C | C | C | C | C |