All values are nominal values and subect to product tolerances Disclaimer: The Information contained in this publication is a general description of glass products and GUARDIAN hereby disclaims all liability howsoever arising from any inaccuracy in or omissions from this publication and all the consequences of relying on it. It is the responsibility of the users of this information to ensure that the intended application of glass products is appropriate and complies with all relevant laws, regulations, standards, codes of practices and other requirements.
GUARDIAN EUROPE Sàrl
19, rue du Puits Romain
L-8070 Bertrange
G-D of Luxembourg
 



ClimaGuard® Solar Bronze
EN 1096-4:2005
Coated soda lime silicate glass intended to be used in buildings and construction works values as of November 2018
04mm
Resistance to fire test NPD
Reaction to fire A1
External fire performance NPD
Bullet resistance (EN 1063) NPD
Explosion resistance NPD
Burglar resistance (EN 356) NPD
Pendulum body impact resistance (EN 12600) NPD
Resistance against sudden temperature changes and temperature differentialsK40
Wind, snow, permanent and imposed load resistancemm4
Direct airborne sound insulation (EN 12758)dB29 (-2; -3)
Thermal properties  
Normal emissivity of coated glass surface εn (EN 12898) 0.03
Radiation properties  
Light transmission τV (EN 410) 0.45
Light reflection (coated side / glass side) ρV (EN 410) 0.11 / 0.24
Solar energy transmission τE (EN 410) 0.30
Solar energy reflection (coated side / glass side) ρE (EN 410) 0.35 / 0.38
Solar factor (coated side / glass side) g (EN 410) 0.39 / 0.35
Durability (EN 1096) C
NPD = No Performance Determined